For inputs and outputs, the option X12 interface with I/O (via integrated module in the cabinet with X12 cabling) can be ordered.
The X12 interface is sufficient when having a small number of I/Os (16 I/20 Os).
X12 interface with I/Os via CAN module in the cabinet, with X12 wiring
Technical data
- 16 digital inputs (type IEC 1131 - 2)
- 2 groups of 8 inputs
- Common ground
- Programmable filter time
- 16 low-current outputs
- max. 500 mA per output
- 2 groups of 8 outputs
- Shared voltage supply within each group
- Error signaling for each group
- 4 high-current outputs (24 V)
- max. 2 A per output
- Shared ground
- Outputs with external voltage supply and protection against overcurrent, overvoltage, overtemperature and short circuit.
- Inputs and outputs insulated from one another and from the bus